EF12  Screw-on from front side Rocker non-illuminated white
Screw-on from front side
Rocker non-illuminated
white
EF12  Screw-on from front side Rocker illuminated orange
Screw-on from front side
Rocker illuminated
orange
EF12  Screw-on from front side Rocker non-illuminated white
EF12  Screw-on from front side Rocker illuminated orange

Series: EF12

IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)

Free Sample Request

16 Variants


Connectors (Inlets/Outlets)

C20
Connector Logo
70° C

Description

  • Panel mount: Screw-on mounting front side
  • 3 Functions: Appliance Inlet Protection class I, circuit breaker type TA45 2-pole, Line filter in standard and medical version
  • Quick connect terminals 6.3 x 0.8 mm

Characteristics

  • All single elements are already wired
  • Circuit Breaker non-illuminated or illuminated
  • With EMC-shield
  • For applications according IEC/UL 62368-1 we recommend variants with bleed resistor
    Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP)

Other versions on request

  • Variant with notch for V-Lock mating Cordsets

Ratings IEC

12 - 16 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

12 - 20 A @ Ta 40 °C / 250 VAC; 60 Hz

Leakage Current

standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)

Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-10 °C to 55 °C

Climatic Category

10/055/21 acc. to IEC 60068-1

IP-Protection

front side IP40 acc. to IEC 60529

Protection Class

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Quick connect terminals 6.3 x 0.8 mm

Panel Thickness S

Screw: max 8 mm
Mounting screw torque max 0.5 Nm

Material

Thermoplastic, black, UL 94V-0

Appliance inlet/-outlet

C20 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 16 A, Protection Class I

Circuit Breakers

Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235
2-pole rocker switch, illuminated or non-illuminated. Optional with undervoltage- or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A

Line Filter

Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8
Technical Details

MTBF

> 100'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: EF12

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 40001520
Approval marks cURus UL UR File Number: E72928


Product standards

Product standards that are referenced

Organization Design Standard Description
Approval marks IEC Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Approval marks IEC Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Approval marks IEC Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Approval marks UL Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Approval marks UL Designed according to UL 1283 Passive filters for suppressing electromagnetic interference
Approval marks CSA_Group Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Approval marks CSA_Group Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Approval marks IEC Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements
Approval marks IEC Suitable for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Approval marks Zulassung_Symbol_UKCA SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_50_non_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
Components V_Lock_Logo SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP)

020060170000001601
LOADING...

Dimension [mm]

* --- Version TA45 with undervoltage release

Diagrams

Standard version

1) Line
2) Load
Medical Version (M5)

1) Line
2) Load

Technical Data of Filter-Components

Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ]
12 Standard version 2 x 0.8 100 2.2 1
16 Standard version 2 x 0.6 100 2.2 1
20 Standard version 2 x 0.3 100 2.2 1
12 Medical Version (M5) 2 x 0.8 100 - 1
16 Medical Version (M5) 2 x 0.6 100 - 1
20 Medical Version (M5) 2 x 0.3 100 - 1

Attenuation Loss

12 A

16 A

20 A

12 A

16 A

20 A


Time-Current-Curves

Tripping Characteristics In < 3 A

Tripping Characteristics In ≥ 3. . . < 18 A

Tripping Characteristics In ≥ 18 A


Effect of ambient temperature

Ambient Temperature [°C] Correction factor
-10 0.89
-5 0.91
0 0.92
+23 1.00
+30 1.03
+40 1.08
+55 1.16


Short Table of Variants EF12 Open complete table EF12

Circuit Breakers

Variant Details


A=Most Popular Free Sample Distributor Stock Check ...
Rated Current [A]   Rocker colour   Illumination   Add-on modules   Order Number                
 
12 black non-illuminated - EF12.1034.3110.01 ...
15 black non-illuminated - EF12.0885.2110.01  A  ...
15 black non-illuminated - EF12.1089.1110.01 ...
16 black non-illuminated - EF12.0034.2110.01 ...
16 black non-illuminated - EF12.0699.2110.01  A  ...
16 black non-illuminated - EF12.2105.2110.01 ...
16 black non-illuminated - EF12.3103.2110.01 ...
20 black non-illuminated - EF12.0035.1110.01  A  ...
20 black non-illuminated - EF12.0572.1110.01  A  ...
20 black non-illuminated - EF12.1164.1110.01 ...
20 black non-illuminated - EF12.2196.1110.01 ...
20 black non-illuminated - EF12.2561.1110.01 ...
20 black non-illuminated - EF12.2961.1110.01 ...
20 black non-illuminated - EF12.3197.1110.01 ...
16 black non-illuminated - EF12.0699.2210.01 ...
20 black non-illuminated - EF12.0035.1210.01 ...

Most Popular.

Packaging unit 16 Pcs 

020060170000001601
LOADING...
Alternative: version without line filter (1)

[Swipe to the left and right for more options]

Mating Outlets/Connectors (3)

[Swipe to the left and right for more options]

4795

4795, Mounting: Power Cord, Cable Connector: IEC C19

4790

4790, Mounting: Power Cord, Screw Connector: IEC C19

0104U

0104U, Mounting: Power Supply Cord, Screw clamps Connector: IEC C19

Mating Outlets/Connectors shuttered (1)

[Swipe to the left and right for more options]

VAC19KS

VAC19KS, Overview, V-Lock cord retaining, diverse Connector IEC C19, diverse, black

Accessories (1)

[Swipe to the left and right for more options]

Cord retaining kits

Cord retaining strain relief


16.05.2024
   
en prod By changing the catalog version (Desktop <> Mobile), the system is resetting the chosen filters